• Call us now: 0903236486
  • Email: info@vntechco.vn

Categories

LS G100 series

Availability : In stock
Liên hệ để báo giá

General Drive The G100 is the optimal solution for a wide range of industrial applications with its high performance, quality and reliability.

Compare

Specification

3-Phase 200V Class (0.4~7.5kW)

 G100-20004000800150022004000550075
Motor RatingHeavy Duty (HD)(HP)0.51.02.03.057.510
(kW)0.40.751.52.24.05.57.5
Normal Duty (ND)(HP)1.02.03.057.51015
(kW)0.751.52.24.05.57.511
Output RatingCapacity [kVA]Heavy Duty (HD)1.01.93.04.26.59.112.2
Normal Duty (ND)1.22.33.84.66.911.415.2
Rated Current
(3-Phase Input) [A]
Heavy Duty (HD)2.55.08.511.017.024.032.0
Normal Duty (ND)3.16.09.612.018.030.040.0
Rated Current
(1-Phase Input) [A]
Heavy Duty (HD)1.52.84.66.19.312.817.4
Normal Duty (ND)2.03.65.96.79.816.322.0
Frequency [Hz]0~400Hz (IM sensorless: 0~120Hz)
Voltage [V]3-Phase 200~240V
Input RatingVoltage [V]3-Phase 200~240VAC (-15%~+10%)
Frequency [Hz]50~60Hz (±5%)
Rated Current [A]Heavy Duty (HD)2.24.98.411.818.525.834.9
Normal Duty (ND)3.06.310.813.119.432.744.2
Weight [kg]1.041.061.361.41.893.083.21

3-Phase 400V Class (0.4~7.5kW)

 G100-40004000800150022004000550075
Motor RatingHeavy Duty (HD)(HP)0.51.02.03.057.510
(kW)0.40.751.52.24.05.57.5
Normal Duty (ND)(HP)1.02.03.057.51015
(kW)0.751.52.24.05.57.511
Output RatingCapacity [kVA]Heavy Duty (HD)1.01.93.04.26.59.112.2
Normal Duty (ND)1.52.43.95.37.612.217.5
Rated Current
(3-Phase Input) [A]
Heavy Duty (HD)1.32.54.05.59.012.016.0
Normal Duty (ND)2.03.15.16.910.016.023.0
Rated Current
(1-Phase Input) [A]
Heavy Duty (HD)0.71.42.12.84.96.48.7
Normal Duty (ND)1.31.92.83.65.48.712.6
Frequency [Hz]0~400Hz (IM sensorless: 0~120Hz)
Voltage [V]3-Phase 380~480V
Input RatingVoltage [V]3-Phase 380~480VAC (-15%~+10%)
Frequency [Hz]50~60Hz (±5%)
Rated Current [A]Heavy Duty (HD)1.12.44.25.99.812.917.5
Normal Duty (ND)2.03.35.57.510.817.525.4
Weight [kg]1.02 (1.04)1.06 (1.08)1.4 (1.44)1.42 (1.46)1.92 (1.98)3.08 (3.24)3.12 (3.28)

Control

Control MethodV/F, Slip Compensation, Sensorless Vector Frequency Setting
Frequency Setting ResolutionDigital command: 0.01Hz
Analog command: 0.06Hz(maximum frequency: 60 Hz)
Frequency Accuracy1% of the maximum output frequency
V/F PatternLinear, squared, user V/F
Overload CapacityHD: 150% 1 minute, ND: 120% 1minute
Torque BoostManual/Automatic torque boost

Operation

Operation ModeSelect key pad, terminal strip, or communication operation
Frequency SettingAnalog: -10~10[V], 0~10[V], 4~20[mA] Digital: Keypad
Operation FunctionPID control, 3-wire operation, Frequency limit, Second function, Anti-forward and reverse direction rotation,
Commercial transition, Speed search, Power braking, Leakage reduction, Up-down operation, DC braking,
Frequency jump, Slip compensation, Automatic restart, Automatic tuning,
Energy buffering, Flux braking, Fire mode
InputMulti-Function Terminal
(5 Points)
NPN (Sink) / PNP (Source) Selectable
Function: Forward run, Reverse run, Reset, External trip, Emergency stop, Jog operation,
Multi-step frequency-high, middle, low, Multi-step acceleration/ deceleration-high, middle, low,
DC braking at stop, 2nd motor select, Frequency up/down, 3-wire operation,
Change into normal operation during PID operation Change into main body operation during option operation,
Analog command frequency fixing, Acceleration/deceleration stop etc. Selectable
Analog InputV1: -10~10V, I2 4~20mA
OutputMulti-function Relay TerminalFault output and drive operation status output(N.O., N.C.) less than AC 250V 1A, less than DC 30V 1A
Analog Output0~12Vdc: Frequency, Output current, Output voltage, DC stage voltage etc. selectable

Protective Function

TripOver current trip, external signal trip, ARM short
current fault trip, over heat trip, input imaging trip,
ground trip, motor over heat trip,
I/O board link trip, no motor trip, parameter writing trip,
emergency stop trip, command loss trip,
external memory error, CPU watchdog trip,
motor light load trip
Over voltage trip, temperature sensor trip,
inverter over heat, option trip,
output image trip, inverter overload trip,
fan trip, pre-PID operation
failure external brake trip,
low voltage trip during operation, low voltage trip,
analog input error, motor overload trip,
over torque trip, under torque trip
AlarmCommand loss trip warning, overload warning, light load warning, inverter overload warning,
fan operation warning, braking resistance braking rate warning, rotor time constant tuning error,
inverter pre-overheat warning, over torque warning, under torque warning
Momentary Power LossHD below 15ms (ND below 8ms): Continuous operation (To be within rated input voltage,
rated output) HD above 15ms (ND above 8ms): Automatic restart operation enable

Environment

Cooling TypeForced fan cooling structure
Protection DegreeIP20/UL Open (Default), UL Enclosed type 1 (Option)
Ambient TemperatureAmbient temperature under the condition of no ice or frost.
HD: -10~50℃(14~122°F) / ND: -10~40℃(14~104°F)
[However, recommended to use load below 80% when using at 50°C under light load]
HumidityRelative humidity below 95% RH (no dew formation)
Storage Temperature-20~65℃(-4~149°F)
LocationNo corrosive gas, flammable gas, oil mist and dust etc. indoors (Pollution degree 2 environment)
Altitude, VibrationBelow 1,000m (From 1000 to 4000m, the rated input voltage and rated output current
of the drive must be derated by 1% for every 100m.), below 9.8m/sec2 (1G)
Pressure70~106kPa